TIMER RTC manual A mode can be set for multiple time periods,can reach 5 time periods;With a buzzer alarm function. OPE:relay closing time point , CLE:relay off time point Time period PE-1-PE-5 5 time periods ( OPE to CLE is a time period) "----":function shielding P-1:The relay closes or outputs pulses every day to the OPE time point , and the relay turns off or outputs pulses to the CLE time point . P-2:set the day , to the OPE time point when the relay closed or output pulse , to the CLE time point when the relay disconnect / or output pulse. P-3:set the date of the month,to the OPE time point when the relay closed or output pulse,to the CLE time point when the relay is off or output pulse . P-4:Set the date 1 to date 2 , start every day at the OPE time point , end to the CLE time point , relay action or output pulse . P-5:As with P-4,only the month can not be set. Parameter setting First , how to set the time? In the time to run the interface , press the DOWN button for a while: Step 1:Select the time period:PE-1~PE-5 Press UP and DOWN to select; Step 2: Press the SET key to select the mode : P-1~P-5( Set this time period to the corresponding mode ) by pressing the UP and DOWN keys.("----"means to block this time period). Note : Each time period can be repeated from the "----",P-1~ P-5 one of the optional ; For example , you can let five time periods at the same time work in the P-1 mode, or let Time period 1 work in P-1 mode,time period 2 work in P-2 mode and so on Step 3 : After the mode selection is finished , press the SET key to enter the time period setting interface , set the interface in the time period , press the SET key to switch the parameter , "OPE" start time point , "CLE"end point , "dAE" date information; Step 4 : After setting the parameters to exit the settings ,press the SET button for 2 seconds to release , auto matically check whether the parameter settings are legal , legal to save the parameters , return to the time to run the interface ; if the parameter is wrong , "ERR"eminder ( for example , stop time or Date < = start time or date ) , return to the parameter setting interface;Additional features:Each "time period"can be set individually In the specific parameter setting intertace ( after the second step ) , press the STOP button to switch the output mode: OUT1:Start time point turns on the relay , the end time is off the relay; OUT2: Outputs 1S pulse to start or end time ; In the specific parameter setting intertace ( after the second step ) , press the STOP button for a while to switch the ringing mode: BLL0 : Ring disable BLL1 : Ring enable Note : When the bell rings , press any button to stop thering. Extended functions STOP key function expansion : Relay enable mode: 1. ON : enable relay on; 2 .OFF : Do not turn on the relay , it is always off; Press the STOP button on the time display interface to switch between ON and OFF,the current status will flash , and then return to the main interface . ( This function is the emergency stop function , press once to close the closed relay) After the relay is disabled , the product can be used as an alarm clock. Sleep mode: 1 . C-P sleep mode : within five minutes , without any operation , the digital display automatically shut down the display , the program normal operation ; 2 . O-d normal mode : digital tube is alwavs open display;Press the STOP button for a while after 2 seconds to release,to achieve C-P and O-d state of the switch , the current state will flash,and then return to the main interface.